2026-03-10
![]()
Note: The neutral wire is marked —— N and must not be connected to any other power wires. After connection, check that the voltage and frequency match the equipment requirements.
Correct operation: Pull up the adjustment knob first. Turn clockwise to increase pressure, counterclockwise to decrease pressure.
Note: The knob must be pulled up; failure to do so may cause damage.
Moisture in the air pipe will shorten the service life of air compressor components. Although an air pressure proportional valve is installed at the air inlet to filter moisture, in humid environments, a large amount of water vapor may still enter the pneumatic components.
In such cases, install a refrigerated air dryer to completely remove moisture, or frequently drain water from the filter cup and air compressor storage tank.
(1) Maintain air pressure between 5–7 kg/cm² at all times.
(2) The middle oil filter cup has an automatic drainage function. If excessive water accumulates, drain it manually.
Note: Replenish grease at grease nipples every 3–6 months to ensure proper lubrication.
Do not use excessive solvent to clean the paint or control panel, as solvents may damage the paint, cause rust, or damage switches and electrical parts.
★ Use only specified oil; avoid thick oil to prevent clogging.
| No. | Maintenance Part | Daily | Weekly | Quarterly |
|---|---|---|---|---|
| 1 | Air Compressor | √ | ||
| 2 | Air Pressure Proportional Valve | √ | ||
| 3 | Clean Ink on Machine | √ | ||
| 4 | Lift Reducer — Engine Oil | √ | ||
| 5 | Lift Reducer — Lubrication | √ | ||
| 6 | Connecting Rod & Joint Bearing Lubrication | √ | ||
| 7 | Column Guide Rail Lubrication | √ | ||
| 8 | Beam Guide Rail Lubrication | √ | ||
| 9 | Printing Head Lift Guide Rail Lubrication | √ | ||
| 10 | Printing Blade Switch Lubrication | √ |
※ All electrical components must be protected from water and solvents to avoid short circuits.